Datamodel changes

The extension alters the standard datamodel, below is a summary of these modifications to help you integrate it with your own extensions.

Note: The following includes datamodel changes from the simple version of the extension as well.

Modified classes

Location

Fields

Code Change type Description
locationtype_id Added (force) External key to LocationType
parent_id Added (if not exists) Hierarchical key to self (Location)
locations_list Added (if not exists) Linked set to child Location objects
accesspermissions_list Added (if not exists) Linked set of access permissions

FunctionalCI

Fields

Code Change type Description
accesspermissions_list Added (if not exists) Linked set of access permissions

Rack

Fields

Code Change type Description
nb_u Replaced (redefine) Height in units (U)
units_order Added (define) Whether the Us are ordered from bottom to top (regular) or from top to bottom (reverse)
occupancy_rate_f Added (define) Occupancy rate of the front panel. Note that obsolete elements are NOT included
occupancy_rate_r Added (define) Occupancy rate of the rear panel. Note that obsolete elements are NOT included
weight Added (define) Weight of the Rack itself
cumulated_weight Added (define) Weight of the Rack. Note that obsolete elements are NOT included
max_allowed_weight Added (define) Maximum weight allowed in this Rack, should either be from the Rack specs or the room specs
used_weight_capacity Added (define) Cumulated weight over max. allowed weight
cumulated_power_input Added (define) Total expected power consumption of all the elements. Note that obsolete elements are NOT included
contracted_power Added (define) Contracted power (kVA)
power_reading_value Added (define) Power reading (kVA)
power_reading_date Added (define) Reading date
power_reading_usage Added (define) Power reading (%)
datacenterslot_list Added (define) All the DatacenterSlot of this Rack, either for misc. equipments (cables, patch panels, …) or future elements

Methods

Name Change type Description
GetInitialStateAttributeFlags Added (define) Force some (computed) fields to be read-only
GetAttributeFlags Added (define) Force some (computed) fields to be read-only

Presentation

The details zlist is completely redefined to propose a nice presentation.

Enclosure

Fields

Code Change type Description
nb_u Replaced (redefine) Height in units (U)
position_v Added (define) Vertical position (U) of the Enclosure in the Rack (Must be the bottom position, not top)
position_p Added (define) Enclosure panel (or Rack panel if directly in it) the element is for
units_order Added (define) Whether the Us are ordered from bottom to top (regular) or from top to bottom (reverse)
layout Added (define) Whether to display devices realistically on a grid each having its own width & height; or just simply the number of devices
nb_cols Added (define) For ‘Grid’ layout only. The number of columns of the Enclosure’s grid. It will determine how many devices can fit side by side
occupancy_rate_f Added (define) Occupancy rate of the front panel. Note that obsolete elements are NOT included
occupancy_rate_r Added (define) Occupancy rate of the rear panel. Note that obsolete elements are NOT included
weight Added (define) Weight of the Rack itself
cumulated_weight Added (define) Weight of the Rack. Note that obsolete elements are NOT included
cumulated_power_input Added (define) Total expected power consumption of all the elements. Note that obsolete elements are NOT included
datacenterslot_list Added (define) All the DatacenterSlot of this Rack, either for misc. equipments (cables, patch panels, …) or future elements

Methods

Name Change type Description
GetInitialStateAttributeFlags Added (define) Force some (computed) fields to be read-only
GetAttributeFlags Added (define) Force some (computed) fields to be read-only

Presentation

The details zlist is completely redefined to propose a nice presentation.

DatacenterDevice

Fields

Code Change type Description
nb_u Replaced (redefine) Height in units (U)
position_p Added (define) Enclosure panel (or Rack panel if directly in it) the element is for
position_v Added (define) Vertical position (U) of the device in the Enclosure (or Rack if mounted directly on int). (Must be the bottom position, not top)
position_h Added (define) Horizontal position of the device in its Enclosure (Must be the left side, not right). This ONLY applies if its Enclosure’s layout is set to ‘Grid’
nb_cols Added (define) Width of of the device defined by on how many grid columns it spreads. This ONLY applies if its Enclosure’s layout is set to ‘Grid’
zero_u Added (define) Only set to ‘Yes’ for devices that do not fit in standard racks / enclosures layout (eg. vertical PDU)
weight Added (define) Weight of the device itself
expected_power_input Added (define) Expected power consumption of the device

Presentation

The details zlist is completely redefined to propose a nice presentation.

PDU

Fields

Code Change type Description
enclosure_id Added (define) Enclosure to which the PDU is attached to
nb_u Added (define) Height in units (U)
position_v Added (define) Vertical position (U) of the device in the enclosure (or rack if mounted directly on int). (Must be the bottom position, not top)
position_p Added (define) Enclosure panel (or Rack panel if directly in it) the PDU is for
position_h Added (define) Horizontal position of the PDU in its Enclosure (Must be the left side, not right). This ONLY applies if its Enclosure’s layout is set to ‘Grid’
nb_cols Added (define) Width of of the PDU defined by on how many grid columns it spreads. This ONLY applies if its Enclosure’s layout is set to ‘Grid’
zero_u Added (define) Only set to ‘Yes’ for devices that do not fit in standard racks / enclosures layout (eg. vertical PDU)
weight Added (define) Weight of the PDU itself

Presentation

The details zlist is completely redefined to propose a nice presentation.

New classes

LocationType

Fields

Code Label Type Description
locations_list Locations AttributeLinkedSet List of all locations of this type

DatacenterSlot

Fields

Code Label Type Description
name Name AttributeString Name
org_id Organization AttributeExternalKey Extenral key to the Organization
location_id Location AttributeExternalKey External key to the Location
rack_id Rack AttributeExternalKey External key to the Rack
enclosure_id Enclosure AttributeExternalKey External key to the Enclosure
position_p Panel AttributeEnum Enclosure panel (or Rack panel if directly in it) the slot is for
position_v Vert. position AttributeMHFRackUnit Vertical position (U) of the slot in the Enclosure (or Rack if mounted directly on int). (Must be the bottom position, not top)
position_h Hori. position AttributeInteger Horizontal position of the device in its Enclosure (Must be the left side, not right). This ONLY applies if its Enclosure’s layout is set to ‘Grid’
nb_u Height AttributeMHFRackUnit Height in units (U)
nb_cols Width AttributeInteger Width of the slot defined by on how many grid columns it spreads. This ONLY applies if its Enclosure’s layout is set to ‘Grid’
weight Weight (kg) AttributeDecimal Weight of the slot itself, will be used to compute cumulated weight of its host
expected_power_input Expected consumption (W) AttributeInteger Expected power consumption of the slot
description Description AttributeHTML Description of the slot usage
accesspermissions_list Access permissions AttributeLinkedSet Access permissions for the slot

MiscEquipmentSlot

ReservedSlot

New menus